| |
| |
|
|
|
|
| A Novel Approach for Measuring Electrical Impedance Tomography for Local Tissue with Artificial Intelligent Algorithm
|
|
Full
text: |
PDF(1.86MB) |
|
|
Source |
International Journal of Biometrics and Bioinformatics (IJBB) |
|
Table of Contents |
|
|
Download
Complete Issue PDF(2.3MB) |
|
Volume: 3 Issue: 5 |
| |
Pages: 66-95 |
|
Publication
Date: November 2009 |
|
ISSN
(Online): 1985-2347 |
|
|
|
|
|
Pages |
66 - 81 |
|
Author(s) |
|
|
|
Published
Date |
30-11-2009 |
|
Publisher |
CSC
Journals, Kuala Lumpur,
Malaysia |
|
ADDITIONAL
INFORMATION |
| Keywords Abstract References Cited by Related Articles Collaborative
Colleague |
| |
|
| |
KEYWORDS: Artificial Intelligence, Alopex Algorithm, Divided Electrode Method, Electrical Impedance Tomography, Equivalent Circuit Model, Medical Imaging |
|
|
| |
|
|
| This Manuscript is indexed in the following databases/websites:- |
|
| 1. Directory of Open Access Journals (DOAJ) |
| 2. ScientificCommons |
| 3. Docstoc |
| 4. Scribd |
| 5. PDFCAST |
| 6. Google Scholar |
| 7. CiteSeerX |
| 8. WorldCat |
| 9. refSeek |
| 10. Academic Index |
| 11. Bielefeld Academic Search Engine (BASE) |
| 12. ResearchGATE |
| 13. Socol@r |
| 14. iSEEK |
| |
|
| |
|
|
| This paper proposes a novel approach for measuring Electrical Impedance Tomography (EIT) of a living tissue in a human body. EIT is a non-invasive technique to measure two or three-dimensional impedance for medical diagnosis involving several diseases. To measure the impedance value electrodes are connected to the skin of the patient and an image of the conductivity or permittivity of living tissue is deduced from surface electrodes. The determination of local impedance parameters can be carried out using an equivalent circuit model. However, the estimation of inner tissue impedance distribution using impedance measurements on a global tissue from various directions is an inverse problem. Hence it is necessary to solve the inverse problem of calculating mathematical values for current and potential from conducting surfaces. This paper proposes a novel algorithm that can be successfully used for estimating parameters. The proposed novel hybrid model is a combination of an artificial intelligence based gradient free optimization technique and numerical integration. This ameliorates the achievement of spatial resolution of equivalent circuit model to the closest accuracy. We address the issue of initial parameter estimation and spatial resolution accuracy of an electrode structure by using an arrangement called “divided electrode” for measurement of bio-impedance in a cross section of a local tissue. |
| |
|
| |
|
| |
| 1 |
Walker D. C. Et al, “Modelled current distribution in cervical squamous tissue”, Physiological Measurement, 23(1): 159-168, 2002 |
|
|
| 2 |
Walker D. C. Et al, “Modelling electrical impedivity of normal and premaligant cervical tissue”, Electronic Letters, 36(19):1603-1604, 2000 |
|
|
| 3 |
M. Cheney and D. Isaacson, “Distinguishability in impedance imaging”, IEEE Transactions on Biomedical Engineering, 39: 852–860, 1992. |
|
|
| 4 |
M. Cheney, D. Isaacson, and J. C. Newell, “Electrical impedance tomography,” SIAM Review, 41(1): 85–101, 1999. |
|
|
| 5 |
S Kimura, T Morimoto, T Uyama, Y Monden, Y Kinouchi and T Iritani, “Application of electrical impedance analysis for diagnosis of a pulmonary mass”, Chest Journal, 105: 1679- 1682, 1995 |
|
|
| 6 |
Y. Kinouchi, T. Iritani, T. Morimoto et al, “Fast in vivo measurement of local tissue impedance using needle electrode”, Medical and Biological Engineering and Computing, 35: 486-492, 1997 |
|
|
| 7 |
Xueli Zhao, Y. Kinouchi, E. Yasuno, “A new method for non invasive measurement of multilayer tissue conductivity and structure using divided electrode”, IEEE Transaction on Biomedical Engineering, 51(2): 362-370, 2004 |
|
|
| 8 |
H. Kato, E. Yasuno, Y. Kinouchi, “Electrical impedance tomography for local bological tissue”, Proceeding of 8th International Conference on Control Robotics, Automation and Vision, 942- 946, 2004 |
|
|
| 9 |
V. Cherepenin, A. Karpov, A. Korjenevsky, V. Kornienko, Y. Kultiasov, M. Ochapkin, O. Trochanova and D. Meister, "Three-dimensional EIT imaging of breast tissues: system design and clinical testing", IEEE Transaction Medical Imaging, 21(6): 662-667, 2002 |
|
|
| 10 |
T. Morimoto, Y. Kinouchi, T. Iritani, S. Kimura, Y. Konishi, N. Mitsuyama, “Measurement of the electrical bio-impedance of breast tumors”, Journal of European Surgical Research, 102: 86-92, 1990 |
|
|
| 11 |
R. P. Henderson, J. G. Webster, “An impedance camera for spatially specific measurements of the thorax”, IEEE Transaction on Biomed. Engineering, 25: 250-254, 1978 |
|
|
| 12 |
T. Tang, S. U. Zhang, R. J. Sadleir, “A portable 8-electrode EIT measurement system”, IFMBE Proceeding, 3980-3983, 2007 |
|
|
| 13 |
D. C. Barber, B. H. Brown, “Inverse problems in partial differential equations”, Society for Industrial and Applied Mathematics Philadelphia, 151-164, 1990 |
|
|
| 14 |
P. Metherall, R. H. Smallwood, D. C. Barber, “Three dimensional electrical impedance tomography of the humanthorax”, Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 758 – 759, 1996 |
|
|
| 15 |
B. H. Brown, et al., “Innovative Technology”. Biol. Med. Vol. 15, pp. 1-8, 1994 |
|
|
| 16 |
A. Borsic, C. McLeod, W. Lionheart and N. Lerrouche, “Realistic 2D human thorax modelling for EIT”, Journal of Physiological Measurement, 22(1), 2001 |
|
|
| 17 |
N. Kerrouche, C. N. McLeod, W. R. B. Lionheart, “Time series of EIT chest images using singular value decomposition and Fourier transform”, Physiological Measurement, 22(1): 147- 157, 2001 |
|
|
| 18 |
W. Yan, S. Hong, Z. Shu, R. Chaoshi, “Influences of compound electrode parameter on measurement sensitivity and reconstruction quality in electrical impedance tomography”, Proceedings of International Federation for Medical and Biological Engineering, 6, 2007 |
|
|
| 19 |
Uhlmann G.,” Developments in inverse problems since calderón's foundational paper, harmonic analysis and partial differential equations”, Essays in Honor of Alberto P Calderón, (editors ME Christ and CE Kenig), University of Chicago Press, 1999 |
|
|
| 20 |
B. H. Brown, D. C. Barber, and A. D. Seagar, "Applied potential tomography: possible clinical applications", Clinical Physics and Physiological Measurement, 6: 109-121, 1985. |
|
|
| 21 |
A.V. Korjenevsky, "Electrical impedance tomography: research, medical applications and commercialization", Troitsk Conference on Medical, Physics and Innovations in Medicine", 2006 |
|
|
| 22 |
V. Cherepenin, A. Karpov, A. Korjenevsky, V. Kornienko, Y. Kultiasov, M. Ochapkin, O. Trochanova and D. Meister, "Three-dimensional EIT imaging of breast tissues: system design and clinical testing", IEEE Transaction Medical Imaging, 21(6): 662-667, 2002 |
|
|
| 23 |
V. Cherepenin, A. Karpov, A. Korjenevsky, V. Kornienko, A. Mazaletskaya, D Mazourov and D. Meister, "A 3D electrical impedance tomography (EIT) system for breast cancer detection", Physiological Measurement, 22(1): 9-18, 2001 |
|
|
| 24 |
G. A. Ybarra, Q. H. Liu, G. Ye, K. H. Lim, J. H. Lee, W. T. Joines, R. T. George, “Breast imaging using electrical impedance tomography (EIT)”, Emerging Technology in Breast Imaging and Mammography, American Scientific Publishers, 2007 |
|
|
| 25 |
A. Hartov, N. K. Soni, K. D. Paulsen, “Variation in breast EIT measurements due to menstrual cycle”, Physiological Measurement, 25: 295-299, 2004 |
|
|
| 26 |
O.V. Trokhanova, M.B. Okhapkin, A.V. Korjenevsky, V.N. Kornienko and V.A. Cherepenin "Diagnostic possibilities of the electrical impedance mammography method", Biomeditsinskaya Radioelektronika, 2: 66-77, 2009 |
|
|
| 27 |
Y F Mangnall et al, “Comparison of applied potential tomography and impedance epigastrography as methods of measuring gastric emptying”, Physiological Measurement, 9: 249-254, 1987 |
|
|
| 28 |
B. M. Eyuboglu, B. H. Brown, D. C. Barber, “In vivo imaging of cardiac related impedance changes”, IEEE Magazine Engineering in Medicine and Biology, 8(1): 39 – 45, 1989 |
|
|
| 29 |
H M Amasha, “Quantitative assessment of impedance tomography for temperature measurements in microwave hyperthermia”, Clinical Physics and Physiological Measurement, 9: 49-53, 1987 |
|
|
| 30 |
S. Chaw, E. Yazaki, “The effect of pH changes on the gastric emptying of liquid measured by electrical impedance tomography and pH-sensitive radio telemetry capsule C” Department of Pharmaceutics, The School of Pharmacy, University of London, April 2001 |
|
|
| 31 |
T. P. Ryan, M. J. Moskowitz, K. D. Paulsen, “The dartmouth electrical impedance tomography system For thermal imaging”, IEEE International Conference of Engineering in Medicine and Biology Society, 13(1): 321 – 322, 1991 |
|
|
| 32 |
K.R.Foster and H.P.Schwan, “Dielectrical properties of tissues and biological materials: a critical review”, Critical Reviews in Biomedical Engineering, 17: 25-104, 1989 |
|
|
| 33 |
D.W.Davidson and R.H.Cole, “Dielectric relaxation in glycerol, propylene glycol, and n-propanol”, Journal of Chem. Phys., 19: 1484-1490, 1951 |
|
|
| 34 |
X.Zhao, Y.Kinouchi, and E.Yasuno, “A new method for non-invasive measurement of multilayer tissue conductivity and structure using divided electrode”, IEEE Transaction on Biomedical Engineering, 51(2): 362-370, 2004 |
|
|
| 35 |
X.Zhao, Y.Kinouchi, T.Iritani and et al., “Estimation of multi-layer tissue conductivities from non-invasively measured bioresistances using divided electrodes”, IEICE Transactions on Information and Systems, E85-D(6):1031-1038, 2002 |
|
|
| 36 |
E. Tzanakou, R. Michalak, E. Harth “The alopex process: visual receptive fields by response feedback,” Biol. Cybern., 35: 161-174, 1979 |
|
|
| 37 |
E. Harth, E. Tzanakou, “Alopex, a stochastic method for determining visual receptive field” Vision Research, 14: 1475-1482, 1974 |
|
|
| 38 |
E. Harth, K. P. Unnikrishnan, A. S. Pandya, "The inversion of sensory processing by feedback pathways: A model of visual cognitive functions", Science 237, pp. 184-187, 1987 |
|
|
| 39 |
A. S. Pandya, K. P. Venugopal, "A stochastic parallel algorithm for supervised learning in neural networks", IEICE Trans. on Information and Systems, E77-D(4): 376-384, 1994 |
|
|
| 40 |
A. S. Pandya, R. Szabo, “Alopex algorithm for supervised learning in layered networks", Proc. of International Neural Network Conference, Paris, 1990 |
|
|
| 41 |
K. P. Venugopal and A. S. Pandya, “Alopex algorithm for training multilayer neural networks", Proc. of International Joint Conference on Neural Networks, 1991 |
|
|
| 42 |
A. S Pandya, R. B Macy, “Pattern Recognition with Neural Networks in C++”, CRC Press. Boca Raton and IEEE Press, 1995 |
|
|
| 43 |
P. S. Sastry, M. Magesh, K. P. Unnikrishnan, “Two timescale analysis of the alopex algorithm for optimization”, Neural Computation, 14(11): 2729 – 2750, 2002 |
|
|
| 44 |
S Haykin, Z Chen, S Becker, “Stochastic correlative learning algorithms”, IEEE Transactions on Signal Processing, 52(8): 2200 – 2209, 2004 |
|
|
| 45 |
A. Bia, “Alopex-B: A new, simpler, but yet faster version of the alopex training algorithm”, International Journal of Neural Systems, 11(6): 497-507, 2001 |
|
|
| 46 |
Farzana Kabir Ahmad, Safaai Deris, Nor Hayati Othman, “Toward integrated clinical and gene expression profiles for breast cancer prognosis: A review paper”, International Journal of Biometrics and Bioinformatics, 3(4): 31-47, 2009. |
|
|
| 47 |
Ankur Agarwal, A. S. Pandya, Morrison S. Obeng, “A low power implementation of GMDH |
|
|
| 48 |
Shanthi Dhanushkodi, G.Sahoo , Saravanan Nallaperumal, “Designing an artificial neural network model for the prediction of thrombo-embolic stroke”, International Journal of Biometrics and Bioinformatics, 3(1): 10-18, 2009 |
|
|
| |
|
| |
|
| |
| |
|
| |
|
| |
| |
|
| |
|
| |
|
| Ankur Agarwal : Colleagues
|
|
| A. S. Pandya : Colleagues
|
|
| A. Arimoto : Colleagues
|
|
| Y. Kinouchi : Colleagues
|
|
|
|
|
|
|
|
|
|
|