List of Journals    /    Call For Papers    /    Subscriptions    /    Login
 
 
 
 
 SEARCH
By Author By Title
 
 
ABOUT CSC
 About CSC Journals
 CSC Journals Objectives
 List of Journals
 CALL FOR PAPERS
 Call For Papers CFP
 Special Issue CFP
AUTHOR GUIDELINES
 Submission Guidelines
 Peer Review Process
 Helpful Hints For Getting Published
 Plagiarism Policies
 Abstracting & Indexing
 Open Access Policy
 Submit Manuscript
 FOR REVIEWERS
 Reviewer Guidelines
 FOR EDITORIAL
 Editor Guidelines
 Join Us As Editor
 Launch Special Issue
 Suggest New Journal
 CSC LIBRARY
 Browse CSC Library
 Open Access Policy
  SERVICES
 Conference Partnership Program (CPP)
 Abstracting & Indexing
 SUBSCRIPTIONS
 Subscriptions
 Discounted Packages
 Archival Subscriptions
 How to Subscribe
 Librarians
 Subscriptions Agents
 Order Form
 DOWNLOADS
 
 
 
 
Comparative Calibration Method Between two Different Wavelengths With Aureole Observations at Relatively Long Wavelength
Full text
 PDF(914.8KB)
Source 
International Journal of Applied Sciences (IJAS)
Table of Contents
Download Complete Issue    PDF(6.22MB)
Volume:  2    Issue:  3
Pages:  NULL
Publication Date:   July / August 2011
ISSN (Online): 2180-1258
Pages 
93 - 101
Author(s)  
Kohei Arai - Japan
Xing Ming Liang - Japan
 
Published Date   
05-08-2011 
Publisher 
CSC Journals, Kuala Lumpur, Malaysia
ADDITIONAL INFORMATION
Keywords   Abstract   References   Cited by   Related Articles   Collaborative Colleague
 
KEYWORDS:   Sunphotometer, Calibration, Langley Method, Modified Langley Method, Aureole, Optical Depth 
 
 
This Manuscript is indexed in the following databases/websites:-
1. Directory of Open Access Journals (DOAJ)
2. Scribd
3. Google Scholar
4. Docstoc
 
 
A multi-stage method for calibration of sunphotometer is proposed by combining comparison calibration method between two different wavelengths with aureole observation method for long wavelength calibration. Its effectiveness in reducing the influences for calibration due to molecular and aerosolfs extinction in the unstable turbidity conditions is clarified. By comparing the calculated results with the proposed method and the existing individually calibration method, it is found that the proposed method is superior to the existing method in terms of calibration accuracy. Namely, Through a comparison between ILM and the proposed method using band 0.87um as reference, the largest calibration errors are 0.0014, 0.0428 by PM are lower than that by ILM (0.011,0.0489) for sky radiances with no error and -3~+3%, -5~+5% errors. By analyzing the observation data of 15 days with POM-1 Skyradiometer, the largest standard deviation of calibration constants by PM is 0.02016, and is lower than that by ILM (0.03858). 
 
 
 
 
 
 
 
 
 
 
 
Kohei Arai : Colleagues
Xing Ming Liang : Colleagues  
 
 
 
  Untitled Document
 
Copyrights (c) 2012 Computer Science Journals. All rights reserved.
Best viewed at 1152 x 864 resolution. Microsoft Internet Explorer.
 
  
 
Copyrights & Usage: Articles published by CSC Journals are Open Access. Permission to copy and distribute any other content, images, animation and other parts of this website is prohibited. CSC Journals has the rights to take action against individual/group if they are found victim of copying these parts of the website.